防火卷簾門控制箱是整個(gè)防火卷簾門的技術(shù)核心部分,影響整個(gè)防火聯(lián)動(dòng)系統(tǒng)。在此,我們將介紹防火卷簾門控制箱的接線注意事項(xiàng):請(qǐng)參閱接線盒的接線圖,了解每個(gè)端子的功能和接線要求,然后正確進(jìn)行接線有線。
Fire shutter door control box is the core part of the whole fire shutter door technology, which affects the whole fire linkage system. Here, we will introduce the wiring precautions of the fire shutter door control box: first, please refer to the wiring diagram of the junction box to understand the function and wiring requirements of each terminal, and then conduct the wiring correctly.
確認(rèn)接線正確后,使用500V兆歐表或振動(dòng)器測(cè)試絕緣電阻;要求將電源接線子電動(dòng)機(jī)的接線端子連接到機(jī)箱上,且相互絕緣電阻值不小于300MΩ;如果絕緣電阻符合要求,則可以進(jìn)行電源調(diào)試工作。打開(kāi)電源,檢查"正常"指示燈是否點(diǎn)亮。
After confirming that the wiring is correct, use a 500V megohmmeter or vibrator to test the insulation resistance; It is required to connect the terminals of the power supply sub motor to the chassis, and the mutual insulation resistance shall not be less than 300m Ω; If the insulation resistance meets the requirements, the power supply can be debugged. Turn on the power and check whether the "normal" indicator is on.

如果它沒(méi)有點(diǎn)亮(控制回路已死),則應(yīng)更改電源線中的任何兩相;否則,請(qǐng)更改電源線。手動(dòng)控制卷門的上,下,停止和限制開(kāi)關(guān)。調(diào)整在無(wú)火的情況下,按下"向上"按鈕,卷簾門應(yīng)下降;按下"停止"按鈕,滾動(dòng)門應(yīng)停止運(yùn)行。
If it does not light up (the control circuit is dead), any two phases in the power line should be changed; Otherwise, change the power cord. Manually control the up, down, stop and limit switches of the rolling door. Adjustment in the case of no fire, press the "up" button, the shutter door should be down; Press the "stop" button, the rolling door should stop running.
在測(cè)試運(yùn)行期間,頂部和底部之間可能會(huì)有差異。在這種情況下,您只需要更改兩個(gè)葫蘆的三相接線。然后嘗試確定與運(yùn)行方向相對(duì)應(yīng)的限位是否有效(用手觸摸微動(dòng)開(kāi)關(guān)),當(dāng)該功能不起作用時(shí),應(yīng)更換限位線;然后調(diào)整行程開(kāi)關(guān)的位置以打開(kāi)和關(guān)閉防火百葉窗門。
There may be differences between the top and bottom during the test run. In this case, you only need to change the three-phase wiring of the two hoists. Then try to determine whether the limit corresponding to the running direction is effective (touch the microswitch by hand). When the function does not work, replace the limit line; Then adjust the position of the travel switch to turn on and close the fire shutter door.
閱讀/ Recommended reading
- 濟(jì)南卷簾門:普通卷簾門 卷簾門如何安裝 2025-09-08
- 濟(jì)南卷簾門:防火卷簾門安裝 2025-08-30
- 工業(yè)快速門常見(jiàn)故障有哪些? 2025-08-04
- 濟(jì)南卷簾門:PVC卷簾門使用清潔事項(xiàng) 2025-08-24
- 濟(jì)南卷簾門易生銹部位解析 2025-07-30
- 濟(jì)南卷簾門常見(jiàn)問(wèn)題解析 2025-07-28
- 濟(jì)南卷簾門定制所需資料解析 2025-07-25
- 濟(jì)南卷簾門使用中的調(diào)整要點(diǎn):適配場(chǎng)景與氣候的實(shí)用指南 2025-07-24
濟(jì)南卷簾門:普通人也能看懂的防火卷簾門安裝
2025-09-16
防火卷簾門是一種適用于建筑物較大洞口處的防火,隔熱設(shè)施,產(chǎn)品在設(shè)計(jì)上采用了卷軸內(nèi)藏的特點(diǎn),具有結(jié)構(gòu)合理緊湊。防火卷簾簾面通過(guò)傳動(dòng)裝置和控制系統(tǒng)達(dá)到卷簾的升降。起到防火,隔火作用...